1
Lighted Pushbutton Switch A3C
Cylindrical 12-dia. Series with Superb
Operability, High Visibility, and Compact
Housing
Three models of pushbutton units (round, square,
and rectangular), two types of light-emitting
elements (LED and lamp), and two types of switch
units(switching general-purposeandmicrocurrent/
voltage loads) available.
Models that can be used as an indicator also
available.
Requires only 20 mm mounting depth
Efficiency in wiring improved by terminals arranged
on the same surface.
All LEDs, lamps, lenses, and legends replaceable
without tools
UL (E41515) and CSA (LR45258-31) approved
Ordering Information
Lighted Type
Whenplacingyourorder,specify theindividualcomponent partmodelnumbers ofthepushbuttonunit,LED,lamp, andswitch unit,as listedin
the ordering tables below.
Non-lighted Type
When placing your order, specify the model numbers of the pushbutton and switch units.
Pushbutton Unit Switch Unit
A3Cj-501jA3Cjj-7jjj
A3C A3C
2
Lighted Pushbutton Unit
LED
Button color Rectangular Square Round
Red A3CJ-500R A3CA-500R A3CT-500R
Yellow A3CJ-500Y A3CA-500Y A3CT-500Y
Green A3CJ-500GY A3CA-500GY A3CT-500GY
White A3CJ-500W A3CA-500W A3CT-500W
Note: With the exception of green, all pushbutton units can be
usedwitheitherLEDorincandescentlamps.Sincethehue
of green changes with an incandescent light source, use
the green LED light source listed elsewhere.
Incandescent Lamp
Button color Rectangular Square Round
Red A3CJ-500R A3CA-500R A3CT-500R
Yellow A3CJ-500Y A3CA-500Y A3CT-500Y
Green A3CJ-500G A3CA-500G A3CT-500G
White A3CJ-500W A3CA-500W A3CT-500W
Blue A3CJ-500A A3CA-500A A3CT-500A
Non-lighted Type
Button color Rectangular Square Round
Red A3CJ-500R A3CA-500R A3CT-500R
Yellow A3CJ-500Y A3CA-500Y A3CT-500Y
Green A3CJ-500G A3CA-500G A3CT-500G
White A3CJ-500W A3CA-500W A3CT-500W
Blue A3CJ-500A A3CA-500A A3CT-500A
Black A3CJ-500B A3CA-500B A3CT-500B
Indicator (Same as A3B)
LED
Color Rated voltage
5VDC 12 VDC 24 VDC
Red A3B-005R A3B-012R A3B-024R
Yellow A3B-005Y A3B-012Y A3B-024Y
Green A3B-005G A3B-012G A3B-024G
White A3B-005W A3B-012W A3B-024W
Incandescent Lamp
Rated voltage 6VDC 14 VDC 28 VDC
Model A3B-006 A3B-014 A3B-028
Switch Unit
Configuration Contact Switch action Terminal Degree of protection: IP00
g
Rectangular Square Round
General SPST-NO+
S
P
S
T
N
C
Momentary Solder A3CJ-7011 A3CA-7011 A3CT-7011
purpose SPST-NC Alternate A3CJ-7021 A3CA-7021 A3CT-7021
Micro-load Momentary Solder A3CJ-7111 A3CA-7111 A3CT-7111
y
PCB A3CJ-7112 A3CA-7112 A3CT-7112
Alternate Solder A3CJ-7121 A3CA-7121 A3CT-7121
PCB A3CJ-7122 A3CA-7122 A3CT-7122
For indication only (no switch) Solder M2CJ-7001 M2CA-7001 M2CT-7001
y
(
)
PCB M2CJ-7002 M2CA-7002 M2CT-7002
A3C A3C
3
Specifications
Contact Ratings
Model Item
AC resistive load DC resistive load
General-purpose
load 0.5 A, 250 VAC
1 A, 125 VAC 1A,30VDC
Micro
current/voltage
load (see note)
0.1 A, 125 VAC 0.1A,30VDC
Note: The minimum permissible load is 1 mA, 5 VDC.
LED Ratings
Rated voltage Rated current Operating voltage
5VDC 30 mA 5VDC
!5%
12 VDC 15 mA 12 VDC!5%
24 VDC 10 mA 24 VDC!5%
Lamp Ratings
Rated voltage Rated current Operating voltage
6V 60 mA 5V
14 V 40 mA 12 V
28 V 24 mA 24 V
Applicable Load Range
Characteristics
Operating frequency Mechanical:
Momentary-action type: 120 operations per minute max.
Alternate-action type: 60 operations per minute max.
Electrical: 20 operations per minute max.
Insulation resistance 100 M"min. (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 minute between terminals of different polarity and also between
each terminal and ground
Vibration Mechanical/malfunction durability: 10 to 55 Hz, 1.5 mm double amplitude
Shock Mechanical durability: 500 m/s2(approx. 50 G)
Malfunction durability: 150 m/s2(approx. 15 G)
Ambient temperature Operating: --10#Cto55
#C
Humidity 35 to 85% RH
Life expectancy Mechanical:
Momentary-action type: 1,000,000 operations min.
Alternate-action type: 100,000 operations min.
Electrical: 100,000 operations min.
Weight Approx. 5 g (see note)
Note: The weight indicated here applies to the lighted type (SPST-NO+SPST-NC).
Operating Characteristics
OF max. 250 g
RF min. 30 g
TT 3.5!0.5 mm
LTA min. 0.5 mm
PT max. 2.5 mm
Approved by Standards
UL (File No. E41515)
CSA (File No. LR45258-31)
Rating
General-purpose Type
1 A, 125 VAC
0.5 A, 250 VAC
1A,30VDC
Microcurrent/Voltage Load
0.1 A, 125 VAC
0.1A,30VDC
A3C A3C
4
Dimensions
The following dimensions apply to the switch unit with SPST-NO+SPST-NC contact configuration, with solder terminals.
Rectangular
A3CJ
Square
A3CA
Round
A3CT
Legend Plate
A3CJ A3CA A3CT
Panel cutout
Panel cutout
15 min.
Note: 1. The thickness is 0.8 mm.
2. Since the legend plate is made of polycarbonate, use alcohol-based paints such as melanin, phthalic acid, or acryl paint when
marking the legend.
A3C A3C
5
Terminals/Connections
Terminal Type
SPST-NO+SPST-NC For indication
Solder terminal Lighted type, non-lighted type
Terminal hole (bottom view)
Indicator
Terminal hole
(bottom view)
PCB terminal Lighted type, non-lighted type
Mounting hole
(bottom view) (bottom view)
6.1
Indicator
Mounting hole
(bottom view) (bottom view)
A3C A3C
6
Accessories (Order Separately)
Name Shape Classification Model Remarks
Socket Wire-wrap terminal A3B-4101 Cannot be used with insulation cover.
PCB terminal A3C-4102
Solder terminal A3C-4103
Insulation
Cover --- A3C-3002 Cannot be used with socket.
Switch
Guard Rectangular A3CJ-5050 Cannot be used with seal cover.
Dust Cover For all shapes A3CJ-5060 Cannot be used with seal cover.
Tightening
Tool --- A3C-3004 Useful for mounting switch units one
after another. Do not over-tighten.
Extractor --- A3PJ-5080 Cannot be used with seal cover.
Legend
P
l
t
Rectangular A3CJ-5201 One legend plate is supplied per
t
d
d
i
t
h
i
t
g
Plate Square A3CA-5201
g
p
p
p
p
standard switch unit.
Round A3CT-5201
Dimensions with Socket
Wire-wrap Terminal PCB Terminal Solder Terminal
Terminal Hole Mounting Hole (Bottom View)
A3C A3C
7
Dimensions with Switch Guard
Panel Cutout (Top View)
Dimensions with Insulation Cover
The following dimensions apply to the rectangular pushbutton unit.
After mounting the switch unit on a panel, and after tightening the
mounting nut, insert the lead wires into the hole on the insulation
cover before wiring.
Aligntheinsulationcoversothatthecylindricalportionoftheinsula-
tion cover will face the switch unit. This means that the lead wires
willbeinsertedfromthebarriersideoftheinsulationcover.Afterwir-
ing has been completed, slide the insulation cover over the switch
unit.
Insulation cover attached to switch
Assembly/Disassembly
Mounting and Replacing Pushbutton Unit
Mounting directions for the LED/lamp and pushbutton unit
TheOMRONPushbuttonUnitdoublestherolesinwhichapushbut-
ton switch is normally used. The pushbutton unit may be inserted
one of two ways:
1. Foroperationasalightedpushbuttonswitch,fittheLED/lamp
sopthatitsguideprojectionisinsertedintothewideropening
in the receptacle of the pushbutton unit.
2. For operation as an indicator unit, insert the LED/lamp guide
projection into the narrower opening in the indicator unit’s
receptacle.PushtheprojectionoftheLED/lampinthegroove
of the pushbutton unit so that the LED/lamp is firmly inserted
into the pushbutton unit of the indicator unit.
Note: The inserting direction of the LED/lamp for the pushbutton
unit is the opposite of that for the indicator unit. Pay atten-
tion to the mounting direction of the legend plate.
A3C A3C
8
Removing the Pushbutton Unit
Withyourthumbandforefinger,whileholdingtherecessedportions
on both sides, firmly and steadily pull out the top of the pushbutton
unit. Pulling out the cap with pliers or a similar tool will damage the
cap.
Mounting Switch Unit on Panel
Nut Mounting
$Insert the switch unit from the front of the panel and tighten the
mounting nut inserted from the rear of the panel.
$Since a projection exists on the rear portion of the switch unit, if
the mounting nut cannot be fitted into position, turn the nut
slightly.
$The tightening torque of the mounting nut should be less than
5kg-cm.
$Solder the terminals after mounting the nut. Otherwise, the
terminals, when thickened by solder, may prevent the nut from
being screwed down onto the switch unit.
Wiring
$Finishsolderingwithin5secondswitha30wattsolderingiron,or
within 3 seconds at a solder temperature of 240#C. For about a
minute after soldering, do not apply any force to the switch unit,
to avoid deforming the softened plastic switch unit base.
$Use a non-corrosive, resin-based soldering flux.
Construction
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. A030-E1-3